Description
Applications:
The Anesthesia machine makes a good performance in Intensive Care Units (ICU), Operation room, Anesthesiology Department and other departments. This model is designed for ease of use, incorporating basic function and the maximum patient safety in daily anesthesia practice. Professional design for adult, child and infant inhalation anesthesia and respiratory management, with advanced ventilation
mode. Combine proven ventilation technology with the latest refinements in ergonomics and systems integration with an advanced, easy to use anesthesia table designed together with experienced experts to streamline your anesthesia workflow.
Features:
7” TFT LCD screen displays the Ventilation parameters, Alarm information and Oscillogram.
High precision flowmeter, instantly know the fresh gas flow to your patient.
Integrated breathing circuit design, ensure easy operating and keep tidy.
Multiple working modes such as volume control and pressure limit, adapt to wide range patient.
Vaporizer with temperature, pressure, flow compensation and self-lock function , keep safety anytime.
Multiple parameters monitoring interface, make every parameter clear, let users know the patient conditions
in all aspects.
Pressure-time, flow-time oscillogram show in real time.
Vital sign monitor and Anesthetic gas monitor are optional.
Technical Specification:
Ventilation mode | IPPV, A/C, SIMV, SIGH, MANUAL |
Ventilator parameter range | Flowmeter: O2(0.1~10L/min)
N2O(0.1~10L/min) Rapid oxygen supply: 25 L/min~75 L/min |
Monitoring parameter | Frequence: 0 /min~100 /min Tidal volume (Vt): 0 mL~2000 mL MV: 0 L/min~100 L/min Oxygen concentration: 15 %~100 % |
Alarm and protection | The AC power failure alarm: Power failure or no connection Low voltage alarm for back up battery: <11.3±0.3V No tidal volume: ≤5mLwithin 6s High oxygen concentration alarm: 19%~100% Low oxygen concentration alarm: 18%~99% High airway pressure alarm: 20 cmH2O~100 cmH2O Low airway pressure alarm: 0 cmH2O~20 cmH2O High minute volume alarm: Adult (5 L/min~20 L/min) Paed (1 L/min~15 L/min) Low minute volume alarm: 0~10 L/min Continuous pressure alarm: (PEEP+1.5 kPa) over 16s Suffocation warning: 5s~60s no spontaneous ventilation The maximum limited pressure: <12.5kPa Fan error: Show on screen Oxygen deficit: Show on screen |
Working condition | Gas source: O2, N2O
Pressure: 280kPa~600kPa Voltage: 100~240V Power frequency: 50/60Hz |
Oscillogram | P-T (pressure- time) P-T (flow-time) |
Reviews
There are no reviews yet.